Inductive components

Inductive components from TRAMAG

Solutions for power quality

Special solutions for power quality and power supply purposes based on proven TRAMAG competencies and technologies.

We provide inductive components for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of inductive components from TRAMAG

Technical characteristics and quality features

Inductive components: Technical characteristics

  • Rated voltage: Depending on the model 200-690 V
  • DC link voltage: Depending on model 400-980 V
  • Clock frequency: Max. 8k Hz
  • Protection classes: IP23, IP00

Inductive components: Quality features

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

Power supplies and DC power supplies from TRAMAG

Power supplies for your applications

Our single-phase and three-phase power supply units, DC power supplies and individual special solutions will power your applications. Guaranteed.

We provide power supplies for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of TRAMAG power supplies and DC power supplies

Technical characteristics and quality features

Power supplies: Technical characteristics

  • Rated voltage: Depending on the model 200-690 V
  • Base frequency: Up to 800 Hz
  • Clock frequency: Max. 8k Hz
  • Protection classes: IP23, IP00

Power supplies: Quality features

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

Reliable LHF Filters from TRAMAG

For the reduction of harmonics in the input network

LHF filters are used upstream of the frequency converter to reduce harmonics in the input network.

We provide LHF filters for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of LHF filters from TRAMAG

Technical characteristics and quality features

LHF filters: Applications

The prerequisite for the use of LHF filters is a line-side fuse protection of the LHF and a converter-side circuit breaker, as well as a line choke.

LHF filters: Technical characteristics

  • Rated voltage: Depending on the model 200-690 V
  • DC link voltage: Depending on model 400-980 V
  • Clock frequency: Max. 8k Hz
  • protection classes: IP23, IP00

LHF-Filter: Quality features

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

Air coils from TRAMAG

As replacement loads in test rigs

Air coils from TRAMAG are used as replacement loads for component testing in test stands.

We carry air coils for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of air coils from TRAMAG

Technical characteristics and quality features

Air coils: Applications

Due to the inductive components made of copper wire, air coils are particularly suitable for use in test equipment.

Air coils: Technical characteristics

  • Current up to 10,000 A
  • Mains voltage up to 1,000 V
  • Frequency up to 1,000 Hz

Air core coils: Quality characteristics

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

d
netzdrosseln-tramag

Double deck chokes

Double deck chokes from TRAMAG

For power regeneration in the grid

TRAMAG double deck chokes are used for power regeneration on the mains side due to their reduced harmonics. In effect, it is an LCL filter without capacitors.

We offer double deck chokes for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of double deck chokes from TRAMAG

Technical characteristics and quality features

Double deck chokes: Applications

The double deck choke is a combination of line and filter choke and is often used in photovoltaic systems for “clean” power regeneration in the grid.

Double deck chokes: Technical characteristics

  • Current up to 10,000 A
  • Mains voltage up to 1,000 V
  • Frequency up to 1,000 Hz

Double deck chokes: Quality features

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

Load chokes from TRAMAG

As replacement loads for motors

Load chokes from TRAMAG are used as replacement loads for motors in test benches.

We provide load chokes for the following industries

You already know exactly what you need?

Request a quote now!

Load chokes from TRAMAG

Technical characteristics and quality features

Load chokes: Applications

Our load chokes are used for testing single and multi-phase traction converters, as well as individual circuit breakers. Ideal for use in test systems and test equipment.

Load chokes: Technical characteristics

  • Current up to 10,000 A
  • Mains voltage up to 1,000 V
  • Frequency up to 1,000 Hz

Load chokes: Quality features

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

Smoothing chokes from TRAMAG

For reduction of residual ripple

TRAMAG smoothing chokes reduce the AC residual ripple on the output side of a rectifier in DC operation.

We offer smoothing chokes for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of smoothing chokes from TRAMAG

Technical characteristics and quality features

Smoothing chokes: Applications

Power electronic plants rely on smoothing chokes from TRAMAG. They ensure the reliable operation of starting converters and compensate high short-time loads.

Smoothing chokes: Technical characteristics

  • Current up to 10,000 A
  • Mains voltage up to 1,000 V
  • Frequency up to 1,000 Hz

Smoothing chokes: Quality features

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

Motor chokes from TRAMAG

For smoothing the output signal

Motor chokes from TRAMAG provide smoothing of the output signal on the output side of an inverter.

We offer motor chokes for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of motor chokes from TRAMAG

Technical characteristics and quality features

Motor chokes: Applications

You need motor chokes as basic protection between frequency converter and motor? We have the right product for you.

Motor chokes: Technical features

  • Current up to 10,000 A
  • Mains voltage up to 1,000 V
  • Frequency up to 1,000 Hz

Motor chokes: Technical characteristics

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

Commutating chokes from TRAMAG

To increase EMC safety

Commutating chokes from TRAMAG are used prior to the input of an inverter to smooth current peaks and increase EMC safety.

We provide commutating chokes for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of commutating chokes from TRAMAG

Technical characteristics and quality features

Commutating chokes: Applications

TRAMAG commutating chokes are used to ensure that the flow of current within the individual current branches is trouble-free and increases performance.

Commutating reactors: Technical features

  • Current up to 10,000 A
  • Mains voltage up to 1,000 V
  • Frequency up to 1,000 Hz

Commutating reactors: Quality features

  • DIN EN 61558-2-20
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

Inductive components

TRAMAG Premagnetizing transformers

For the reduction of the switch-on current

TRAMAG premagnetizing transformers are used to premagnetize MV/HV transformers and thus reduce the switch-on current.

We provide premagnetizing transformers for the following industries

You already know exactly what you need?

Request a quote now!

Specifications of TRAMAG premagnetizing transformers

Technical characteristics and quality features

Premagnetizing transformers: Applications

Are you faced with the question of how to limit the switch-on current in your project? The solution: premagnetizing transformers from TRAMAG.

Premagnetizing transformers: Technical characteristics

  • Power rating 1 MVA
  • Voltages up to 1,000 V
  • Frequency typ. 50-60 Hz

Premagnetizing transformers: Quality features

  • DIN EN 60601-1
  • DIN EN 61558-2-1
  • DIN EN 61558-2-4
  • DIN EN 61558-2-6
  • UL/CSA
Transformer production – Innovative and reliable since 1923
Precisely fitting solutions for every application.

TRAMAG News

Always up to date on transformers


27. May 2024

REDUR & TRAMAG AT PCIM EUROPE

A joint presence with a strong, innovative range of products for high-performance electrotechnical applications in drives, automation and testing technology…

Learn more
2. May 2024

TRAMAG Transformatorenfabrik is a new member of REDUR

We are pleased to announce that with REDUR GmbH & Co. KG we found an excellent buyer for TRAMAG Transformatorenfabrik GmbH & Co. KG as of 2 May 2024 and we are proud to be a new member of REDUR and the Phoenix Mecano family.

Learn more
22. January 2024

TRAMAG is alive, operations continue unabated at full power!

TRAMAG is alive, operations continue unabated at full power! “The trick is to get up once more than you are knocked down.” (Winston Churchill) All hands on deck, the TRAMAG […]

Learn more
20. December 2023

Christmas & New Year Greetings

The TRAMAG Team would like to thank its customers, business partners and friends for the trust they have placed in us and for their cooperation in partnership over the past year. 2023, another year full of business challenges, but also a year of suffering and misfortune for many people in regions near and far around the world.

Learn more
18. December 2023

Quality is when your QMB goes “High-Five-S” with you

We know where quality must ultimately be demonstrated and proven: In the product, in the customer’s application. But where does quality begin? On the one hand in technical development and on the other hand in the organization of workplaces in production. Employees who keep their workstations tidy maintain an overview, have access to the right tools at all times and can work on the product efficiently and with quality assurance.

Learn more

Stay tuned!
English content coming soon!

close
Transformatoren Spezialist Transformatoren Spezialist

TRAMAG News

News from transformer, choke and filter technology

Inform now